Skip to product information
1 of 1

Royal

Royal Pump Assembly - CE7000 Steam Vacuum, Plant Code TE

Royal Pump Assembly - CE7000 Steam Vacuum, Plant Code TE

Regular price $34.99 USD
Regular price Sale price $34.99 USD
Sale Sold out
Shipping calculated at checkout.

SKU:440008533

55 in stock

Free Shipping On Orders $100+
Genuine Parts OEM Quality
Secure Checkout SSL Encrypted

Shipping Information

We offer FREE shipping on orders of $100 or more within the continental United States.

Orders typically ship out from our store within 1-5 business days, and most orders arrive 2-11 business days after they are placed. Special order items may require additional processing time.

Returns & Exchanges

We offer a 35-day return policy on all unused items in original packaging. A Return Authorization (RA#) is required.

To initiate a return, please contact our customer service team. Return shipping costs may apply for non-defective items.

Warranty Information

All products sold by Vacuums and More come with the manufacturer's warranty. Warranty terms vary by brand and product.

With 35 years of industry experience, we stand behind every product we sell. Contact us for warranty support.

View full details

Royal Pump Assembly - CE700...

$34.99

Product details

This is the pump assembly for the Royal CE7000 carpet extractor, part 440008533, built to plant code TE. The pump pushes cleaning fluid out across the carpet just ahead of the extraction stroke that pulls it back up.

When the pump fails, the machine can still sound and suck normally while doing nothing useful, since the water path and the vacuum path are separate systems. Three signs point to this pump: solution flow that cuts out entirely when you squeeze the trigger, a stream that pulses on and off instead of running steady, or liquid collecting on the floor beneath where the pump sits. Any of these means cleaning solution is not reaching the carpet, so the machine is running an extraction pass on dry carpet without actually cleaning it. Running the machine on plain water for a few minutes after a repair is a good way to confirm flow is steady before putting it back into regular use.

  • Fits: Royal CE7000 steam vacuum, plant code TE
  • Part: Pump assembly, part 440008533
  • Common cause of failure: Sediment buildup from hard water or old detergent residue
  • Before ordering: Check the code stamped on your machine's data plate, since this part is built specifically for the TE version

After fitting, reconnect every hose fitting securely, then run the machine on plain water for a test cycle before returning it to service.