Skip to product information
1 of 2

Electrolux

Electrolux PU3650 Central Vacuum LCD Control Module

Electrolux PU3650 Central Vacuum LCD Control Module

Regular price $181.99 USD
Regular price Sale price $181.99 USD
Sale Sold out
Shipping calculated at checkout.

SKU:102020

Free Shipping On Orders $100+
Genuine Parts OEM Quality
Secure Checkout SSL Encrypted

Shipping Information

We offer FREE shipping on orders of $100 or more within the continental United States.

Orders typically ship out from our store within 1-5 business days, and most orders arrive 2-11 business days after they are placed. Special order items may require additional processing time.

Returns & Exchanges

We offer a 35-day return policy on all unused items in original packaging. A Return Authorization (RA#) is required.

To initiate a return, please contact our customer service team. Return shipping costs may apply for non-defective items.

Warranty Information

All products sold by Vacuums and More come with the manufacturer's warranty. Warranty terms vary by brand and product.

With 35 years of industry experience, we stand behind every product we sell. Contact us for warranty support.

View full details

Electrolux PU3650 Central V...

$181.99

Product details

The LCD panel on a PU3650 power unit is not just a screen, it is tied directly to the low-voltage board that switches the motor on and off, so a fault here usually affects both what you see and whether the unit responds at all. This module replaces that combined display and control board.

Built for the PU3650 power unit, the model Electrolux sold as the QuietClean, and listed by parts retailers under part 102020 for exactly this platform. A dark or scrambled display, missing run-time or service indicators, or a unit that no longer starts when a wall inlet opens are the typical signs this board has failed rather than the motor or the wiring elsewhere in the system.

  • Fits: Electrolux PU3650 power unit
  • Type: Combined LCD display and low-voltage control board
  • Function: Status readout plus motor on/off switching
  • Symptoms it addresses: Blank or garbled display, unresponsive start/stop

Before replacing the board, cut power to the power unit at its breaker for a full minute and restore it. Some display faults on this platform are a stuck logic state rather than a hardware failure, and a clean power cycle clears them without spending on a new board. If the display comes back scrambled or stays dark after that reset, the board itself is the more likely cause.

Because the display and the switching logic share one board on this platform, a screen problem is worth treating as a possible control fault even if the unit still seems to start, since intermittent switching failures often show up on the display first, before they cause a full no-start. Keep the old board until the new one is confirmed working normally, in case a wiring issue elsewhere turns out to be the actual cause. Listed under SKU 102020.